Datacentres

 
domain registration | webhosting | reseller webhosting | dedicated server | VPS virual private server | hosted exchange | colocation | rackspace | streaming media
dedicated server
rackspace
Datacentres Specifications

TrancePitt Services has its own Private Cage, a clearly separated room on a shared floor, facilitated at Tele2/Versatel in Amsterdam, which guarantees safety and privacy.

Our server space is watched 24/7 by means of video surveillance.

TrancePitt Services also makes use of a second data centre, the Databarn, in Amsterdam. Below you will find a description of both data centres.
 

Gyrocenter Amsterdam   Databarn Amsterdam
The Gyrocenter data centre is a relatively young, but because of that, a modern data centre. Among other things it is used by Tele2 to broadcast television through the internet., so the Gyrocenter meets the highest telecom demands, which are many times higher than those of a standard data centre. The Gyrocenter is also ISO 9001 and ISO 27001, which implies that everything has to be conducted in accordance with a safety protocol.   The Databarn data centre has been existing for many years; in 2006 it was taken over and became vacant. Since TrancePitt Services was looking for space in the proximity of the Gyrocenter, the Databarn has become our second location. The Databarn is a very modern, well-organised data centre, which even might be called state-of-the-art.
     
Security   Security
The Gyrocenter is watched 24 hours a day by means of CCTV (Closed Circuit Television), which registers anything and anyone in and around the data centre. In order to reach the TrancePitt Services Cage, you will get a PAC key card (Proximity Access Card). With this card you can solely enter the data centre and the TrancePitt Services Cage; all the other doors cannot be opened with the key card. In case of an emergency engineers and guards are present 24 hours a day to solve the problems.   The Databarn is watched 24 hours a day by means of CCTV (Closed Circuit Television), which registers anything and anyone in and around the data centre. In order to reach the TrancePitt Services room, you will get a PAC key card (Proximity Access Card). With this card you can solely enter the data centre and the TrancePitt Services room; all the other doors cannot be opened with the key card. In case of an emergency engineers and guards are present 24 hours a day to solve the problems.
     
Emergency Power Supplies (UPS)   Emergency Power Supplies (UPS)
The Gyrocenter has been equipped with two UPS (Uninterruptible Power Supply) systems, which supply the data centre with power in case of a power cut: So, first of all, the data centre is supplied with emergency power by batteries. In the meantime the three diesel generators will have been activated, which can supply the Gyrocenter with power for 48 hours.   The Databarn has been equipped with a complete wall of UPS (Uninterruptible Power Supply) systems, which in the event of a power cut, will supply the data centre with power for 45 minutes. In the meantime the three diesel generators will have been activated, which can supply the Gyrocenter with power for 48 hours. The data centre also contains a load bank which can test the UPS at any moment without risking loss of electric power.
     
Air Conditioning (Climate Control)   Air Conditioning (Climate Control)
The air conditioning, better called climate control, keeps the temperature of the data floor at a constant temperature of 21° C, with a discrepancy of 2° C. Apart from this, the air humidity is regulated: it is kept between 50% and 10%. Climate control contributes to a longer life of your and our equipment.   The air conditioning, better called climate control, has been executed redundantly and keeps the temperature of the data floor at a constant temperature of 21° C, with a discrepancy of 2° C. Apart from this, the air humidity is regulated: it is kept between 50% and 10%. Climate control contributes to a longer life of your and our equipment.
     
Fire Detection and Fire Prevention   Fire Detection and Fire Prevention
The Gyrocenter has been equipped with an aspiration smoke detection system which has been linked to VESDA (Very Early Smoke Detection Apparatus). Even more important is the MIST fire extinguishing system: In case of a fire the data floor is filled with the oxygen replacing Argon gas: the fire will be extinguished due to lack of oxygen. The equipment will not be affected by the Argon gas.   The Databarn has been equipped with an aspiration smoke detection system which has been linked to VESDA (Very Early Smoke Detection Apparatus). In case of a smoke detection the fire will not be extinguished automatically, but in the entire building manual CO2 extinguishers are present: within ten minutes guards will be there to extinguish the fire.
     
Access to the Gyrocenter   Access to the Databarn
With TrancePitt Services you have access to the Gyrocenter 24 hours a day; you can report at our CRM-system without telephone intervention and you can even do so by using your PDA, if you are on your way to the Gyrocenter.   With TrancePitt Services you have access to the Databarn 24 hours a day; you can report at our CRM-system without telephone intervention and you can even do so by using your PDA if you are on your way to the Databarn.
dediacted server
dedicated server colocatie
dedicated server
rackspace
Gyrocenter Datacentre
dediacted server
dedicated server colocatie
dedicated server
rackspace
Databarn Datacentre


dediacted server
dedicated server colocatie
dedicated server
rackspace
Private Cage


dediacted server
dedicated server colocatie
dedicated server
rackspace
Rittal Racks


dediacted server
dedicated server colocatie
datacentre  |  network  |  support  |  noc  |  contact  |  general terms  |  add to favorites  |  partners  |  sitemap  |  disclaimer